Osburn Matrix 2700 Wood Insert

Item #: OB02700

SKU:

  • Expert Support
  • Secure Checkout
  • Warranty Included
  • Reliable Delivery

Starting at:

$4,299.00

Customize Your Product

Door Overlay *

Black Door Overlay

OA10253

Brushed Nickel Door Overlay
(+$250.00)

OA10254

Optional Items

Liner Insert Kit

(+$788.00)

6" x 15"

(+$924.00)

6" x 20"

(+$1,006.00)

6" x 25"

(+$1,114.00)

6" x 30"

(+$1,214.00)

6" x 35"

(+$1,322.00)

6" x 40"

(+$1,443.00)

6" x 45"

(+$1,518.00)

6" x 50"

Insulation Kit

(+$320.00)

1/4 Inch Thick x 25 ft. Length

(+$415.00)

1/4 Inch Thick x 35 ft. Length

(+$315.00)

1/2 Inch Thick x 15 ft. Length

(+$368.00)

1/2 Inch Thick x 25 ft. Length

(+$420.00)

1/2 Inch Thick x 30 ft. Length

(+$496.00)

1/2 Inch Thick x 35 ft. Length

Product price: $4,299.00
Order total:

Returns may be subject to a 20% restocking fee. Shipping and processing fees are non-refundable.

  • Free Shipping on Orders Over $99
  • Product Support Available
  • Secure Checkout
  • Trusted Payment Methods

Product Description

The widest view, and the cleanest burn, of any Osburn insert

An insert has one job an open masonry fireplace cannot do: keep the heat in the room. Your existing fireplace pulls warm household air up the flue and sends most of the fire's output with it. A sealed insert with a dedicated liner reverses that, and the Matrix 2700 does it while producing just 1.2 g/h of particulate — the lowest figure across the Osburn insert range.

It also has the widest door in the line at 25⅝", which matters more than the spec sheet implies. A wide, low viewing area reads as a fireplace; a small square porthole reads as an appliance. The Matrix 2700 is the one that still looks like a fire once it is in the wall.

Cleaner burn, less creosote, cheaper sweeps

Low particulate output is not only an emissions statistic. Unburned particulate is what condenses in your liner as creosote, and creosote is what feeds chimney fires. A unit burning at 1.2 g/h deposits substantially less than an older stove running at 4 or 5. You will notice it in your annual service.

Non-catalytic combustion, so there is no combustor to degrade and replace every few seasons.

The liner is not optional

This is the part people underestimate when pricing an insert. A wood insert must be connected to a continuous stainless liner running the full height of the chimney — listed to ULC-S635, CAN/ULC-S640 or UL1777 — with a minimum of 15 ft of chimney height for adequate draft.

You cannot vent an insert into an unlined masonry flue. Budget the liner, the insulation and the labour alongside the appliance; it is a meaningful share of the total, and we would rather you hear that now than at install.

Specifications

  • Firebox: 22⅝" wide · EPA loading volume 1.94 cu ft
  • Overall: 43⅝"W x 27¼"D x 30⅛"H
  • Door opening: 25⅝"W x 10½"H, single glass with cast iron frame
  • Emissions: 1.2 g/h particulate · 98 g/h CO · EPA approved
  • Non-catalytic, C-Cast or equivalent baffle
  • Requires listed stainless liner · minimum 15 ft chimney
  • Fuel: dry cordwood, 16" recommended

Send us the width, height and depth of your existing fireplace opening and we will confirm the Matrix 2700 fits before you order — and quote the liner in the same breath. (540) 212-9374

Specifications

Type of Chimney: Liner - ULC-S635, CAN/ULC-S640, UL1777
Minimum Chimney Height: 15'
Fuel Type: Dry cordwood (16" recommended)
Door Style: Single, glass with cast iron frame
Door Opening Height: 10 1/2"
Door Opening Width: 25 3/8"
EPA Approved: Yes
EPA Loading Volume: 1.94
Average Particulate Emissions Rate: 1.2 g/h
Average CO: 98 g/h
Combustion Technology: Non-catalytic
Baffle Type: C-Cast or equivalent
Overall Width: 43 5/8"
Overall Depth: 27 1/4"
Overall Height: 30 1/8"
Firebox Width: 22 5/8"
Firebox Depth: 12 7/8"
Firebox Height: 12 3/8"
Firebox Volume: 2.5
Chimney Diameter: 6"
Flue Outlet Diameter: 6"
Heating Sq Ft: 750 - 2,200
Maximum Burn Time: 8h
Overall Heat Output Rate: 12,700 BTU/h (3.72 kW) to 60,700 BTU/h (17.79 kW)
Maximum Heat Output: 80,000 BTU/h (23.4 kW)
Efficiency: 64%
Optimum Overall Efficiency: 70%
Optimum Heat Transfer Efficiency: 68%
Maximum Log Length: 20"
Glass Viewing Area: 24 3/8" X 12 5/8"
Blower Included: Yes
Blower CFM: 176
Glass Color: Ceramic glass
Item Weight: 535 lb (243kg)
Approved for a Mobile Home Installation: No

Minimum Clearances to Combustibles

The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites). Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
Data expressed in inches. 1 inch = 25.4 mm (Single Wall Pipe / Double Wall Pipe) Single Wall Pipe Double Wall Pipe
Clearance - Side Wall 19"
Clearance - Top (Measured From the Platform on Which the Appliance Is Installed) 84"
Clearance – Minimum Floor Protection in Front of the Appliance 16"

Video

FAQs

Q: Why is the efficiency as per the EPA’s test data smaller than the publicized optimum efficiency?

A: EPA refers to the CSAB415.1-10 standard for the calculation of the appliance’s efficiency. The efficiency reported as per EPA’s directives consists of an average between four different burn rates, ranging from the lowest burn rate (air intake completely closed) to the highest burn rate (air intake completely open). The optimum efficiency that we publicize is the efficiency obtained according to the same test data, but for the low burn rate only. This efficiency is more realistic for a majority of users whose heating needs require that the unit be used to maximize burn times.

Q: Why is the BTU according to EPA test data smaller than the one advertised?

A: You will notice a difference between the BTU output as per the EPA’s test data and what is advertised on our web site and/or product literature. The maximum BTU output we advertise is what will be obtained with a full load of seasoned cordwood inserted inside the firebox. The EPA output, on the other hand, is what has been obtained during emissions testing. The EPA test procedure requires that a special type of wood is used and positioned inside the firebox in a manner that does not represent the way the firebox volume would normally be utilized using seasoned cordwood. The EPA test load is typically much smaller. Hence, the BTU as per the EPA’s test data is reduced. The BTU output that should be considered by a normal user is the one we advertise for seasoned cordwood.

Q: Will my insert work in the case of a power failure?

A: Your insert can be used in a power failure. An insert is built like a wood stove. The only thing that will not work in a power failure is the blower. Operating your insert without the blower will not damage the unit. The disadvantage is that you will not benefit from the heat circulation around the insert’s jacket. Inserts come with a blower because a large portion of the unit is inserted into a masonry opening. The heat that radiates from the portion of the firebox inserted into the masonry hearth does not reach the room as it would with a freestanding wood stove. This is why inserts have a jacket built around the back portion of their firebox. The heat is trapped inside that jacket and is pushed back in front of the stove and into the room with a blower. Without electricity, you will not recover as much heat from the unit. The radiating heat will come mainly from the glass and the front portion of the insert.

Q: Why does my wood insert blower not move a lot of air?

A: All of our inserts and blowers are designed to complement each other. It is a matter of achieving the greatest amount of heat transfer from the unit. The key is to design the insert so air can move and extract the greatest amount of heat without cooling the firebox and hindering the efficiency of the unit. If the blower velocity were to be increased, it would give the impression that the unit heats more. However, it would actually blow cooler air and reduce the unit's efficiency. A hot firebox will burn better and cleaner. A slower but hotter air displacement is therefore always preferable. The same principle applies to the heat sensor available on many models. It is better for the heat sensor to activate the blower later, when the unit is very hot, rather than activating it too early and blow cooler air when the unit is still completing its start-up phase.

Q: Can I install a liner with a 5-inch or 5.5-inch diameter?

A: All of our inserts are designed to function with a 6" liner. However, it is adequate to install a 5" or 5.5" liner when the masonry chimney is too tight for a 6" liner. Under certain conditions, the probability of a drafting issue is increased, which could favor smoke spillage and/or reduce combustion quality. But generally speaking, the vast majority of homeowners who properly install a 5" or 5.5" liner and use good heating techniques will be very satisfied with the performance of their wood insert.

More Questions?

  • Secure Checkout
  • Trusted Payment Methods
  • Manufacturer Warranty Included
  • Expert Customer Support
  • Fast & Reliable Delivery

© 2026 First Response Fireplace Products, All rights reserved

Request a Quote

Please fill out the form below to provide us with more information. One of our experts will contact you after submission.
You can also call our experts (540) 212-9374
*Required
Checkbox*

Freight Shipping

After processing, your order will ship and should arrive within 5-7 business days, depending on your location
Your order comes with free lift gate service. The freight driver will use a lift gate to unload the shipment and place it curbside at your home. You’ll need to move the shipment from the curb to the end location. Please make sure your street can accommodate a tractor-trailer.
Upon delivery, you’ll be asked to sign the Proof of Delivery (POD). Before signing, inspect the shipment for visible damage. If damaged, refuse the shipment and call us for a replacement. Damage to products inside the shipment must be reported within 3 business days of delivery.